Abstract

Introduction. Bloodstream infections (BSI) are growing in incidence and present a serious health threat. Most patients wait up to 48 h before microbiological cultures can confirm a diagnosis. Low numbers of circulating bacteria in patients with BSI mean we need to develop new methods and optimize current methods to facilitate efficient recovery of bacteria from the bloodstream. This will allow detection of positive blood cultures in a more clinically useful timeframe. Many bacterial blood recovery methods are available and usually include a combination of techniques such as centrifugation, filtration, serum separation or lysis treatment. Here, we evaluate nine different bacteria recovery methods performed directly from blood culture.

Aim. We sought to identify a bacterial recovery method that would allow for a cost-effective and efficient recovery of common BSI pathogens directly from blood culture.

Methods. Simulated E. coli ATCC 25922 blood culture was used as a model system to evaluate nine different bacteria recovery methods. Each method was assessed on recovery yield, cost, hands-on time, risk of contamination and ease of use. The highest scoring recovery method was further evaluated using simulated blood cultures spiked with seven of the most frequently occurring bloodstream pathogens. The recovery yield was calculated based on c.f.u. count before and after each recovery method. Independent t-tests were performed to determine if the recovery methods evaluated were significantly different based on c.f.u. ml−1 log recovery.

Results. All nine methods evaluated successfully recovered E. coli ATCC 25922 from simulated blood cultures although the bacterial yield differed significantly. The MALDI-TOF intact cell method offered the poorest recovery with a mean loss of 2.94±0.37 log c.f.u. ml−1. In contrast, a method developed by Bio-Rad achieved the greatest bacterial yield with a mean bacteria loss of 0.27±0.013 log c.f.u. ml−1. Overall, a low-speed serum-separation method was demonstrated to be the most efficient method in terms of time, cost and recovery efficiency and successfully recovered seven of the most frequent BSI pathogens with a mean bacteria loss of 0.717±0.18 log c.f.u. ml−1.

Conclusion. The efficiency of bacterial recovery can vary significantly between different methods and thereby can have a critical impact on downstream analysis. The low-speed serum-separation method offered a simple and effective means of recovering common BSI pathogens from blood culture and will be further investigated for use in the rapid detection of bacteraemia and susceptibility testing in clinical practice.

Close

Details

Original languageEnglish
Pages (from-to)806-811
Number of pages6
JournalJournal of Medical Microbiology
Volume69
Issue number6
DOIs
Publication statusPublished - 3 Jun 2020

    Research areas

  • Bloodstream infection, Blood culture and bacterial recovery

Discover related content
Find related publications, people, projects and more using interactive charts.

View graph of relations

Related by author

  1. Real-time monitoring of live mycobacteria with a microfluidic acoustic-Raman platform

    Baron, V. O., Chen, M., Hammarstrom, B., Hammond, R. J. H., Glynne-Jones, P., Gillespie, S. H. & Dholakia, K., 14 May 2020, In : Communications Biology. 3, 8 p., 236.

    Research output: Contribution to journalArticle

  2. Can phenotypic data complement our understanding of antimycobacterial effects for drug combinations?

    Kloprogge, F., Hammond, R., Copas, A., Gillespie, S. H. & Della Pasqua, O., Dec 2019, In : Journal of Antimicrobial Chemotherapy. 74, 12, p. 3530–3536 7 p.

    Research output: Contribution to journalArticle

  3. Mimicking in-vivo exposures to drug combinations in-vitro: anti-tuberculosis drugs in lung lesions and the hollow fiber model of infection

    Kloprogge, F., Hammond, R., Kipper, K., Gillespie, S. H. & Della Pasqua, O., 13 Sep 2019, In : Scientific Reports. 9, 8 p., 13228.

    Research output: Contribution to journalArticle

  4. Sample detection device

    Hammond, R. J. H. & Gillespie, S. H., 12 Sep 2019, Patent No. US 2019 / 0277759 A1, Priority date 18 Nov 2016, Priority No. GBGB1619509.1A

    Research output: Patent

Related by journal

  1. Rapid molecular testing for Staphylococcus aureus bacteraemia improves clinical management

    McHugh, M. P., Parcell, B. J., MacKenzie, F. M. & Templeton, K. E., 1 Apr 2020, In : Journal of Medical Microbiology. 69, 4, p. 552-557 6 p.

    Research output: Contribution to journalArticle

  2. Evaluation of staphylococcus aureus eradication therapy in orthopaedic surgery

    Tsang, S. T. J., McHugh, M. P., Guerendiain, D., Gwynne, P., Boyd, J., Laurenson, I. F., Templeton, K. E., Lewis, S., Simpson, A. H. R. W. & Walsh, T. S., 1 Jun 2018, In : Journal of Medical Microbiology. 67, 6, p. 893-901 9 p., 000731.

    Research output: Contribution to journalArticle

ID: 268623787

Top