Abstract

We report a multimodal optical approach using both Raman spectroscopy and optical coherence tomography (OCT) in tandem to discriminate between colonic adenocarcinoma and normal colon. Although both of these non-invasive techniques are capable of discriminating between normal and tumour tissues, they are unable individually to provide both the high specificity and high sensitivity required for disease diagnosis. We combine the chemical information derived from Raman spectroscopy with the texture parameters extracted from OCT images. The sensitivity obtained using Raman spectroscopy and OCT individually was 89% and 78% respectively and the specificity was 77% and 74% respectively. Combining the information derived using the two techniques increased both sensitivity and specificity to 94% demonstrating that combining complementary optical information enhances diagnostic accuracy. These data demonstrate that multimodal optical analysis has the potential to achieve accurate non-invasive cancer diagnosis. (C) 2013 Optical Society of America

Close

Details

Original languageEnglish
Pages (from-to)2179-2186
Number of pages8
JournalBiomedical Optics Express
Volume4
Issue number10
DOIs
Publication statusPublished - 1 Oct 2013

    Research areas

  • Tissue classification, Principles, Images, Vivo

Discover related content
Find related publications, people, projects and more using interactive charts.

View graph of relations

Related by author

  1. Nonredundant Raman imaging using optical eigenmodes

    Kosmeier, S., Zolotovskaya, S., De Luca, A. C., Riches, A. C., Herrington, C. S., Dholakia, K. & Mazilu, M., 20 Oct 2014, In : Optica. 1, 4, p. 257-263 7 p.

    Research output: Contribution to journalArticle

  2. Combined information from Raman spectroscopy and optical coherence tomography for enhanced diagnostic accuracy in tissue discrimination

    Ashok, P. C., Praveen, B. B., Bellini, N., Riches, A., Dholakia, K. & Herrington, C. S., 4 Mar 2014, Biomedical Vibrational Spectroscopy VI: Advances in Research and Industry. Mahadevan-Jansen, A. & Petrich, W. (eds.). SPIE, Vol. 8939. 7 p. (Proceedings of SPIE; vol. 8839).

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

  3. Discrimination of bladder cancer cells from normal urothelial cells with high specificity and sensitivity: Combined application of atomic force microscopy and modulated Raman spectroscopy

    Canetta, E., Riches, A., Borger, E., Herrington, C. S., Dholakia, K. & Adya, A. K., 7 Jan 2014, In : Acta Biomaterialia. 10, 5, p. 2043-2055 13 p.

    Research output: Contribution to journalArticle

  4. Optimisation of wavelength modulated Raman spectroscopy: towards high throughput cell screening

    Praveen, B. B., Mazilu, M., Marchington, R. F., Herrington, C. S., Riches, A. & Dholakia, K., 25 Jun 2013, In : PLoS One. 8, 6, 5 p., e67211.

    Research output: Contribution to journalArticle

  5. Fluorescence suppression using wavelength modulated Raman spectroscopy in fiber-probe-based tissue analysis

    Balagopal, B., Ashok, P. C., Mazilu, M., Riches, A. C., Herrington, C. S. & Dholakia, K., 9 Jul 2012, In : Journal of Biomedical Optics. 17, 7, 6 p., 077006.

    Research output: Contribution to journalArticle

Related by journal

  1. Three-dimensional imaging of cell and extracellular matrix elasticity using quantitative micro-elastography

    Hepburn, M. S., Wijesinghe, P., Major, L. G., Li, J., Mowla, A., Astell, C., Park, H. W., Hwang, Y., Choi, Y. S. & Kennedy, B. F., 1 Feb 2020, In : Biomedical Optics Express. 11, 2, p. 867-884 18 p.

    Research output: Contribution to journalArticle

  2. Analysis of spatial resolution in phase-sensitive compression optical coherence elastography

    Hepburn, M. S., Wijesinghe, P., Chin, L. & Kennedy, B. F., 28 Feb 2019, In : Biomedical Optics Express. 10, 3, p. 1496-1513 18 p.

    Research output: Contribution to journalArticle

  3. Finger-mounted quantitative micro-elastography

    Sanderson, R. W., Curatolo, A., Wijesinghe, P., Chin, L. & Kennedy, B. F., 1 Apr 2019, In : Biomedical Optics Express. 10, 4, p. 1760-1773 14 p.

    Research output: Contribution to journalArticle

  4. Handheld probe for quantitative micro-elastography

    Fang, Q., Krajancich, B., Chin, L., Zilkens, R., Curatolo, A., Frewer, L., Anstie, J. D., Wijesinghe, P., Hall, C., Dessauvagie, B. F., Latham, B., Saunders, C. M. & Kennedy, B. F., 1 Aug 2019, In : Biomedical Optics Express. 10, 8, p. 4034-4049 16 p.

    Research output: Contribution to journalArticle

  5. Volumetric quantitative optical coherence elastography with an iterative inversion method

    Dong, L. I., Wijesinghe, P., Sampson, D. D., Kennedy, B. F., Munro, P. R. T. & Oberai, A. A., 1 Feb 2019, In : Biomedical Optics Express. 10, 2, p. 384-398 15 p.

    Research output: Contribution to journalArticle

ID: 115279583

Top